Estudo de caso do desempenho acústico de uma igreja localizada em Lajeado

dc.contributor.advisor1Ferreira, Marcelo Freitas
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9746186017182989pt_BR
dc.contributor.referee1Ferreira, Marcelo Freitas
dc.contributor.referee1Spinelli, Rodrigo
dc.contributor.referee1Wojcickoski, Vagner Gonçalves
dc.creatorKoefender, Silas Eliseu
dc.date.accessioned2017-10-20T17:47:22Z
dc.date.available2017-10-20T17:47:22Z
dc.date.issued2017-10
dc.date.submitted2017-07-14
dc.description.abstractCom o crescimento da igreja evangélica no Brasil e, consequentemente, com o surgimento de novas denominações evangélicas, diversos tipos de ambientes têm sido usados com a finalidade de culto, e na maioria das vezes, estes ambientes não possuem parâmetros acústicos adequados para atendimento de tal finalidade. Dessa forma, como as igrejas evangélicas, em geral, utilizam-se da música e do discurso falado em suas reuniões, esta inadequação acaba resultando em uma dificuldade para se alcançar qualidade e conforto acústico em ambas as situações. Para que estas duas atividades não sejam prejudicadas, uma igreja deve apresentar condições acústicas que proporcionem a inteligibilidade tanto da palavra falada quanto da palavra cantada. Este trabalho é um estudo de caso de uma igreja evangélica localizada em Lajeado, RS, através de testes in loco, utilizando-se da excitação por fonte impulsiva para conhecer as respostas que o local a ser analisado dá a essas excitações. As captações destas excitações serão obtidas a partir do software de medições AURORA, para então conhecer os valores dos parâmetros acústicos atuais encontrados na igreja, como Tempo de Reverberação (TR), Tempo de Decaimento Inicial (EDT), Definição (D50), Clareza (C80) e Índice de Transmissão da Fala (STI). Possuindo os valores destes parâmetros, analisar-se-á a qualidade acústica da igreja em questão, para eventualmente propor as melhorias necessárias para alcançar o conforto acústico na igreja para seus devidos fins.pt_BR
dc.description.abstractWith the growth of the evangelical church in Brazil and, consequently, with the emergence of new evangelical denominations, various types of environments have been used for the purpose of worship service, and in most cases, these environments do not have appropriate acoustic parameters to fulfill its purpose. This way, as evangelical churches generally use the music and the spoken speech in their meetings, this inadequacy results in a difficulty to achieve acoustic comfort and quality in both situations. In order for these two activities do not be harmed, a church must have acoustic conditions that provide the intelligibility of both the spoken word and the sung word. This work is a case study of an evangelical church located in Lajeado, RS, through on-site tests, using the excitation by impulsive source to know the answers that the site analyzed gives to these excitations. The captures of these excitations will be obtained from the AURORA measurement software, in order to know the values of the current acoustic parameters found in the church, such as Reverberation Time (RT), Initial Decay Time (IDT), Definition (D50), Clearness (C80) and Speech Transmission Index (STI) . From the values of these parameters, the acoustic quality of the church will be analyzed, in order to eventually propose the necessary improvements to achieve acoustic comfort in the church for its proper purposes.pt_BR
dc.identifier.citationKOEFENDER, Silas Eliseu. Estudo de caso do desempenho acústico de uma igreja localizada em Lajeado. 2017. Monografia (Graduação em Engenharia Civil) – Universidade do Vale do Taquari - Univates, Lajeado, 14 jul. 2017. Disponível em: http://hdl.handle.net/10737/1659. pt_BR
dc.identifier.urihttp://hdl.handle.net/10737/1659
dc.language.isopt_BRpt_BR
dc.rightsopenAccesspt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectParâmetros acústicospt_BR
dc.subjectAcústica de Igrejaspt_BR
dc.subjectInteligibilidadept_BR
dc.subjectTempo de Reverberaçãopt_BR
dc.subject.cnpqENGpt_BR
dc.titleEstudo de caso do desempenho acústico de uma igreja localizada em Lajeadopt_BR
dc.typebachelorThesispt_BR
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2017SilasEliseuKoefender.PDF
Size:
1.95 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections