Análise comparativa de isolamento térmico entre lajes pré-moldadas e laje painel treliçada com a utilização de tavelas cerâmicas e blocos de poliestireno expandido (EPS) para fins de conforto térmico

dc.contributor.advisor1Ferreira, Marcelo Freitas
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9746186017182989pt_BR
dc.contributor.referee1Ferreira, Marcelo Freitas
dc.contributor.referee1Rosa, Ivandro Carlos
dc.contributor.referee1Gravina, João Batista
dc.creatorDalberto, Ebrael
dc.date.accessioned2017-08-21T17:14:17Z
dc.date.available2017-08-21T17:14:17Z
dc.date.issued2017-08
dc.date.submitted2017-07-11
dc.description.abstractAs residências de modo geral, devem oferecer condições térmicas adequadas ao conforto humano. De acordo com a NBR 15575 (ABNT, 2013), a norma atual de desempenho, foi criado alguns requisitos e métodos de avaliação de desempenho para as principais partes que compõem uma edificação, dentre elas: estruturas, coberturas, pisos internos, vedações externas e internas, e instalações hidrossanitárias. Dentre os diversos sistemas construtivos para coberturas em edificações, o uso de lajes pré-moldadas e lajes painéis treliçadas está aumentando na região sul do pais. Usualmente estas lajes são preenchidas com Poliestireno Expandido (EPS) ou com tavelas e blocos cerâmicos. O principal objetivo deste presente estudo é avaliar o desempenho térmico de três lajes; laje pré-moldada com tavelas cerâmicas, laje pré-moldada com EPS, e laje painel treliçada com EPS. Para avaliação dos valores referentes à resistência térmica dos materiais e para a transmitância térmica, será utilizado a NBR 15220-2 (ABNT, 2005) para comprovação da eficiência térmica dos três tipos de lajes. Além disso, será avaliado o principal índice de medição do conforto térmico, o Índice de Temperatura e Umidade (ITU), procedimento realizado com equipamento específico para a coleta de dados de temperaturas internas e externas dos protótipos, assim como a umidade relativa do ar interna. Com estes resultados espera-se poder oferecer uma nova concepção de projetos com melhores desempenhos térmicos que os projetos atualmente utilizados.pt_BR
dc.description.abstractThe residences in general, should offer adequate thermal conditions to human comfort. According to NBR 15575 (ABNT, 2013), the current performance standard, some requirements and methods of performance evaluation were created for the main parts that make up a building, among them: structures, roofs, internal floors, external fences and sanitary facilities. Among the various building systems for roofing in buildings, the use of precast slabs and slabs of latticed panels is increasing in the southern region of the country. Usually these slabs are filled with Expanded Polystyrene (EPS) or with slabs and ceramic blocks. The main objective of this present study is to evaluate the thermal performance of three slabs; Pre-cast slab with ceramic slabs, pre-molded slab with EPS, and slab panel lattice with EPS. For the evaluation of the thermal resistance values of the materials and for the thermal transmittance, NBR 15220-2 (ABNT, 2005) will be used to prove the thermal efficiency of the three types of slabs. In addition, the main index of thermal comfort measurement, the Temperature and Humidity Index (ITU) will be evaluated, a procedure performed with specific equipment to collect internal and external temperature data of the prototypes, as well as the relative humidity of the internal air. With these results it is expected to be able to offer a new conception of projects with better thermal performances than the projects currently used.pt_BR
dc.identifier.citationDALBERTO, Ebrael. Análise comparativa de isolamento térmico entre lajes pré-moldadas e laje painel treliçada com a utilização de tavelas cerâmicas e blocos de poliestireno expandido (EPS) para fins de conforto térmico. 2017. Monografia (Graduação em Engenharia Civil) – Universidade do Vale do Taquari - Univates, Lajeado, 11 jul. 2017. Disponível em: http://hdl.handle.net/10737/1619. pt_BR
dc.identifier.urihttp://hdl.handle.net/10737/1619
dc.language.isopt_BRpt_BR
dc.rightsopenAccesspt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectConforto térmicopt_BR
dc.subjectLaje pré-moldadapt_BR
dc.subjectLaje painel treliçadapt_BR
dc.subjectTavela cerâmicapt_BR
dc.subjectBlocos de EPSpt_BR
dc.subject.cnpqENGpt_BR
dc.titleAnálise comparativa de isolamento térmico entre lajes pré-moldadas e laje painel treliçada com a utilização de tavelas cerâmicas e blocos de poliestireno expandido (EPS) para fins de conforto térmicopt_BR
dc.typebachelorThesispt_BR
Arquivos
Pacote original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem em miniatura
Nome:
2017EbraelDalberto.PDF
Tamanho:
4.83 MB
Formato:
Adobe Portable Document Format
Descrição:
Pacote de licença
Agora exibindo 1 - 1 de 1
Carregando...
Imagem em miniatura
Nome:
license.txt
Tamanho:
4.6 KB
Formato:
Item-specific license agreed upon to submission
Descrição: